HPL
SOCOMEC :
DIRIS
SYSTEM :
DIRIS
Ap offers to users flexibility to use a device based upon needs. The requirement
of the user today may be only multi measurement. The basic model offers
a solution to this need. Add on plug in modules are available to meet
enhanced needs and needs which may arise in the future. These plugin modules
are available for the following selection.
1.
Energy - ± kWh,, ±kVarh And KVAh
2.
Harmonics - To measure odd harmonics on V & I up to 15 harmonic
and THD on V & I for each phase.
3.
Communication - Rs 485 with JBUS / MODBUS Protocol
4.
Analogue Opututs
5.
Alarm& control function
MULTIFUNCTION
ENERGY METERS :
DIRIS
Ap units are universal products (5A to 1A CT Inputs, LV or HV networks
AC or DC auxiliary supply) perfectly suited to meet the requirements of
both Installer and users
DIRIS
: Ap Plug in Modules*
MODULE
1 : Metering
± kWh, ± kVarh and kVAh with two programmable pulse outputs
MODULE
2 : Module 1 + Harmonics
I1, I2, I3, U12, U23, U31, and THD U/I upto harmonic n 15
MODULE
3 : communication
2 or 3 wire RS 485 with JBUS / MODBUS protocol, with Transmission speed
of up to 38,400 bauds
MODULE
5 : Alarm or control and command 2 inputs for pluse / metering or
for input status 2 outputs for alarm monitoring or output command. The
monitoring function allows upper or lower alarm thresholds to be programmed
with time delay and hysteresis options.
The
Panel-mounted solution :
CHARACTERISTICS
:
PRESENTATION
| Display panel |
back
- lit LCD
|
| Key pad Dimensions |
6
direct access keys
96
x 96 x 60 mm (without options)
or
80mm (with options)
|
| Front face
protection |
IP54
|
| Connections |
1
fix terminal for current (6mm)
1
to 56 plug - in terminals for other connections (2.5 mm)
|
| Weight |
400g
|
MEASUREMENT
Current
(insulated inputs
- primary CT :
- secondary CT : |
Consumption
: 0.1VA
up
to 10000A
1
or 5 A
|
| Voltage |
|
- direct :
ph/ph
- primary VT :
- secondary
VT : |
Up
to 700 V AC
Up
to 400 kV
60,
100, 110, 173 and 190V
|
| Maximum CT
x VT ratio |
2,000,000
|
| Frequency |
45
to 65 Hz
|
| AUXILIARY SUPPLY
(AC & DC with the same unit) |
110
to 400 VAC ± 10% - 50/60 Hz
120
to 350 V DC ± 20%
|
| ACCURACY |
|
| Current (I)Voltage
(U) |
0.5
% for I
0.5
% for U
|
| Power (P) |
1%
for P
|
| Active energy |
IEC
1036 class 2
±2%
From 0.02 In to 1.2 IN with PF=0.5 L or C
|
| Reactive energy |
IEC
1268 class2
±2%
From 0.1 In to 1.2 IN with sin = 0.5 l or c
|
| INPUTS |
2
OPTOCOUPLESR (10 TO 30 VDC)
|
| PULSE OUTPUTS |
relays
(100 V DC - 0.5 A - 10 VA)
|
| ALARM OR COMMAND
OUTPUTS |
relays
(250 V AC - 6 A - 1600 VA)
|
| ANALOGUE OUTPUTS |
2
TO 4, 0/4-20 mA outputs
|
ENVIRONMENT
Operating temperature
Storage |
-10
to +55' C (14 to +131' F)
-20
to +85 C (- 4 to + 158' F)
|
| Relative humidity |
95%
|
ON
LOAD CHANGEOVER :
FUNCTIONS
:
HPL
- Socomec are manually controlled ONLOAD CHANGEOVER SWITCHES. They operate
as Changeover giving three stable position (I, O & II) and help in
changeover from one supply source to another.
DESIGN
:
Changeover
Switches are manufactured from SIRCOVER moulded case on load switches
with single handle arrangement. The switch frames are side by side for
63-80A or back to back 125-3150A. The whole range is manually operated.
RANGE
:
Manual
operation : Four pole version HPL - Socomec 63A-3150A
On the
above maintained range, the operating handle is in front position, 'direct'
or 'of door' interlocked type.
CONFORMITY
:
IS
13947 - Part 3
IEC 947-3, IEC 664
BSEN 60947-3
VDE 0680 - NBC 63408
NFEN 60947-3
NFC 12100 (Security Rules, Emergency Sources)
APPROVALS
:
Bureau
Veritas - Lloyds Register of Shipping - Tested at CPRI, Bhopal / Bangalore
SALIENT
FEATURES :
- Safety in
disconnection / on load switching
- A simple,
strong and reliable mechanism provides a total security in disconnection.
The operating handle can be in 'O' position only if all the contacts
are effectively open.
- In the SIRCOVER
Type the contacts opening / making is within polyester reinforced
glass body.
- For all versions,
the quick makes and quick break feature independent of the operating
speed enables the switches to close and open circuits under the
most severe conditions (e. g. highly inductive loads - AC 23A
duty).
- Details Available
on Request.
- The moulded
body's raw material fiber glass reinforced polyester, It has a very
high mechanical strength, self extinguishing and gives a high dielectric
strength to the switches.
- The choice
of this raw material and the surface treatment of the current carrying
part with silver plating enable use of the switches in tropical
conditions (relative humidity 95% 45°C)
- HPL-SOCOMEC
Change-over Switches are ideal choice for installation in cubicles
or cabinets due to compact open execution interiors.
- Strong and
ergonomic handle is padlockable in 'Off' as well as in I & II
Position and has got door interlock feature in 'ON' position. Connection
on terminals in very easy, as they are large and assessable.
GENERAL
CHARACTERISTICS :
- The ideal conception
in HPL - SOCOMEC SIRCOVER Changeover Switches incorporate the following
advantages :- Three stable position (I,O & II) and possible changeover
from one to the other while functioning.
Positions
:
O-Circuits
I and II open (Neutral Position)
I-Circuit - I close and circuit II open (transformer supply on and generator
supply off)
II-Circuit I open and Circuit II close (generator supply on and transformer
supply off)
Contact
System :
- Safety of division
: Clearly apparent operation.
- High thermal
and dynamic strength to withstand rated fused short circuit current
level 80 KA rms.
- Are rated for
AC-23A utilization category.
APPLICATION
:
- The HPL-SOCOMEC
SIRCOVER Changeover Switches are especially designed for control and
disconnection of all kinds of circuits-distribution feeders/.Motor
loads.
- By means of manual
operation, changeover per forms circuit switching and are mainly used
- As a switching
control of two independent circuits (Circuit 1 closing/cirucit
II opening, and vice versa).
AUXILIARY
CONTACTS :
Application
:
The auxiliary contacts are of "OC" type, they provide position
signalization or prebreak control. They are designed with 6.35 mm Fast
on connectors.
Switch
fuse changeover 125A to 630A
RANGE
:
125A,
200A - Frame I
250A, 320A - Frame II
400A, 630A - Frame III
DEFINITION&
FUNCTION :
HPL
SCOMEC switch fuse Changeover is a manually operated 4pole switch fuse
with position I-O-II with backup protective devices as HRC fuses mounted
in RYB phases. The switch is provided with an isolating Neutral &
offers protection in position I as wella s in position II to load connected
to comman outgoing circuit.
CONFORMITY
TO STANDARDS :
Conforms
to IEC947-3-IS : 13947-3 on switch disconnector, Switches & fuse combination
units.
APPROVALS
:
- Tested at CPRI
Bopal for AC-23A utilisatin category test.
- Tested for rated
short circuit fused current capacity at 80KA rms.
FEATURES
:
The
particular conception of HPL SOCOMEC switch fuse Changeover, 4pople gives
the following advantages:
- While breaking
the circuit, guarantees sufficient air sectioning clearance.
- Protection against
overcurrents & short circuit faults by fuses of high rupturing
capacity 80 ka rms.
- Compact &
standardised sizes for range 125A - 630A.Ideal for switch board manufacturers.
- Strong endurance
& resistance to heat (Tropicalised)
- 3 Stable positions
(I-O-II) & possible switching from one to the other on load, thereby
fulfilling the role of switching device with protection for two modes
of supply-one from electricity board & other from standby Source
- generator and providing back up protection.
ACCESSORIES
:
- Barrier plates
- between two individual supply terminals.
- Fuse barrier
between fuses.
AUXILIARY
CONTACTS :
- Auxiliary contacts
upto 2NO. 2NC (optional) for signalisation, interlocking.
BS
EXECUTION (BOLTED TYPE) :
- Available in
6 rating from 125A-630A with 3pole & neutral switched & provided
with HRC fuses on 3 poles for bolted type fuses as per IS : 13703
(part 2/6) 1993/ IEC269-9-101987)
|
RATING
|
SUITABLE
HRC FUSE |
|
Size
|
REF
|
|
125A
|
A-4
|
LK-TCP
|
|
160A
|
A-4
|
LK-TCP
|
|
200A
|
A-4
|
LK-TSFP
|
|
250A
|
B-1
|
LK-TSK
|
|
320A
|
B-1
|
LK-TSK
|
|
400A
|
C-1
|
LK-TSMS
|
|
630A
|
C-1
|
LK-TTS
|
- Front operation
- right side
- External padlockable
handle with door interlocking arrangement mounted on an enclosure
door or on the panel cover
STEEL
ENCLOSURE
- Switch Fuse Changeover
can be supplied in Sheet Steel Enclosures, made of thick guage sheet
steel protected with phosphate coating by seven tank system and powder
coated for long life.
- All enclosures
are fitted with top and bottom end plates with adequately sized knockouts
for cables.
for
more information visit at :
http://www.hplindia.com
TOP
|